GE Power Controls SOLID STATE SOFT STARTER ASTAT Plus USER MANUAL REMARKS: 1. Read this manual throughly before using the ASTAT Plus, and. General Electric/Motor Starter MPN ASTAT-QI3KDP ASTAT Plus Solid State Soft Start 50 HP Model: ASTATQI3KDP B &. Max Volts 3 Phase AC: VAC. Find great deals for GE ASTAT Plus Qi3kdp 50hp Soft Start General Electric 50 HP Starter. Shop with confidence on eBay!.

Author: Tygoshura Zucage
Country: Gabon
Language: English (Spanish)
Genre: Photos
Published (Last): 17 March 2008
Pages: 444
PDF File Size: 3.36 Mb
ePub File Size: 10.58 Mb
ISBN: 558-4-77777-192-6
Downloads: 83444
Price: Free* [*Free Regsitration Required]
Uploader: Kira

Add to watch list Remove from watch list. Please enter a valid ZIP Code.

Delay trip time The unit trips if the current decreases bellow of the percentage set. Permanent command is allowed as well, wiring 1, 2 and 57 terminals as shown in page The parameters of each group can be displayed or skipped according the selection done in parameter astag.

GE ASTAT Plus QI3KDP 50HP Soft Start General Electric 50 HP Starter | eBay

In this case, linear ramp independent of a wide load range is allowed. The programmable relay outputs are as default assigned to the following functions: Combined shipping discounts are built into our shipping calculator.

Learn More – opens in a new window or tab Any international shipping is paid in part to Pitney Bowes Inc. As a general rule it can be guaranteed that soft starter will allow starting of drives which are currently used in conventional starting systems, with the advantages outlined, and above all the facility to adjust the current peaks and torque at the machine, faced with the impossibility or difficulty of varying the steps in conventional systems.

  BERK AND DEMARZO CORPORATE FINANCE PDF

GE ASTAT Plus User Manual

The control signals are optoelectronically isolated and various levels of protection have been set up in the circuits to immunize the equipment against external disturbance and its effects. This is usefull to stop a fan which is rotating in reverse at the starting time Basic diagram with DC brake injection 1.

W – to stop the unit, the command will be: It is usefull to limit hammering. Sets Voltage ramp up time. A tacho generator must be used as feedback.

Unit may contain more than one live circuit. Interest will be charged to your account from the purchase date if the balance is not paid in full within 6 months.

Verify thyristors Stalled rotor Equipment detected stalled motor rotor Restart equipment and check for an appreciable loss in motor speed at any time i.

For additional information, see the Global Shipping Program terms and conditions – opens in a new window or tab No additional import charges on delivery Delivery: Image not available Photos not available for this variation.

Set Rated Value asat x x x Voltage Calibration t 4 0 0 V Setting of this parameter allows better accuracy in monitoring or voltage protections.

Remarks Supply wire conductors should have the same section as direct starters.

GE Astat Plus Soft start Manual

If control power is lost between starts, the overload relay protection is reset to cold start conditions. W – to set the acceleration ramp time to 35sec.

  DELMORE SCHWARTZ POEMS PDF

Have one to sell? Check Appendix section for more details Range Description When the motor thermistor is not used, a link must be set between those terminals. Resume making your offerif the page does not update immediately. This relay must be used to control the DC brake contactor. Ralentissement courant continu peut provoquer la surchauffe de moteur. Asynchronous data transmission, Bauds, 1 asatt start, 8 bits data, 1 bit stop. It’s a community-based project which helps to repair anything.

You may also arrange shipping yourself. Programmable Advanced Functions Display Function Default Range Description This function provides linear acceleration and deceleration ramps in a wider range of load conditions. In this case the bypass is automatically done after starting. This relay can be assigned to several internal output functions.

Reverse jog is also possible by setting “rxxx” to ON.

GE ASTAT PLUS USER MANUAL Pdf Download.

You should use an external overload protection if required by local rules or to protect the motor against current imbalance. See terms – opens in a new window or tab. Command signal may be provided by one NO free voltage push-button to terminals 1 and Mouse over to Zoom – Click to enlarge. The vertical position is essential for proper cool air circulation – Environmental conditions are in accordance with the following astag and maximum values: